• Users Online:128
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 9  |  Issue : 6  |  Page : 385-391

Macroscopic on-site evaluation of biopsy specimens for accurate pathological diagnosis during EUS-guided fine needle biopsy using 22-G Franseen needle


1 Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
2 Division of Pathology, Shizuoka Cancer Center, Shizuoka, Japan
3 Division of Endoscopy; Division of Genetic Medicine Promotion, Shizuoka Cancer Center, Shizuoka, Japan

Correspondence Address:
Dr. Hirotoshi Ishiwatari
Division of Endoscopy, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/eus.eus_49_20

Rights and Permissions

Background and Objectives: Measuring a visible core length during macroscopic on-site evaluation (MOSE) can be useful for accurate diagnoses during an EUS-guided fine needle biopsy (EUS-FNB). We aimed to estimate visible core cutoff lengths predictive of a correct diagnosis when using 22-gauge Franseen needles for biopsies from pancreatic masses. Materials and Methods: We assessed 77 consecutive patients who underwent EUS-FNB using 22-gauge Franseen needles for pancreatic masses between March 2018 and October 2018. At least two needle passes were performed in all patients, irrespective of the findings on MOSE. The endoscopists measured the visible cores using a ruler during MOSE. The first two passes were analyzed on a per pass basis, and the correlation between visible core lengths and diagnostic accuracy was evaluated. Results: We evaluated 150 needle passes of 75 patients. The accuracy per pass was 92% (138/150). The median length of the visible cores was 15 (range: 0–60) mm and they were significantly longer in the correct diagnosis group than in the incorrect diagnosis group. The accuracy correlated positively with the visible core length. Receiver-operating characteristic curve analysis of the visible core length for accuracy demonstrated an optimal cutoff value of 10 mm. On multivariate logistic regression, visible core lengths >10 mm independently affected the correct diagnosis (odds ratio: 5.1, P= 0.02). Conclusions: Visible cores exceeding 10 mm may be useful for correct diagnosis while using a 22-gauge Franseen needle for EUS-FNB from pancreatic masses.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1065    
    Printed53    
    Emailed0    
    PDF Downloaded95    
    Comments [Add]    

Recommend this journal