|
|
IMAGES AND VIDEOS |
|
Year : 2022 | Volume
: 11
| Issue : 2 | Page : 147-148 |
|
Lumen-apposing metal stents salvage that accidentally dislodged during a necrosectomy of a WON (with video)
Dominic Staudenmann1, Sanjivan Mudaliar2, Arthur John Kaffes3, Payal Saxena3
1 AW Morrow Gastroenterology and Liver Centre, Royal Prince Alfred Hospital, Sydney, Australia; Praxis Intesto, Bern, Department of Gastroenterology; Department of Gastroenterology, Université de Fribourg, Fribourg, Switzerland 2 AW Morrow Gastroenterology and Liver Centre, Royal Prince Alfred Hospital; Department of Gastroenterology, Sydney Medical School, University of Sydney, Sydney, Australia 3 AW Morrow Gastroenterology and Liver Centre, Royal Prince Alfred Hospital, Sydney, Australia; Praxis Intesto, Bern, Department of Gastroenterology, Switzerland
Date of Submission | 13-Feb-2021 |
Date of Acceptance | 07-Jul-2021 |
Date of Web Publication | 21-Oct-2021 |
Correspondence Address: Payal Saxena AW Morrow Gastroenterology and Liver Centre, Royal Prince Alfred Hospital, 50 Missenden Road, 2050 Sydney
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/EUS-D-21-00054
How to cite this article: Staudenmann D, Mudaliar S, Kaffes AJ, Saxena P. Lumen-apposing metal stents salvage that accidentally dislodged during a necrosectomy of a WON (with video). Endosc Ultrasound 2022;11:147-8 |
How to cite this URL: Staudenmann D, Mudaliar S, Kaffes AJ, Saxena P. Lumen-apposing metal stents salvage that accidentally dislodged during a necrosectomy of a WON (with video). Endosc Ultrasound [serial online] 2022 [cited 2022 May 22];11:147-8. Available from: http://www.eusjournal.com/text.asp?2022/11/2/147/328595 |
Dominic Staudenmann, Sanjivan Mudaliar
These authors contributed equally to the work.
Around 15% of the patients with acute pancreatitis develop acute walled-off pancreatic necrotic collection (WON). EUS-guided drainage of WONs with lumen-apposing metal stents (LAMS) is an established procedure because it is a minimally invasive approach and with good outcomes.[1],[2],[3] However, deployment of electrocautery-enhanced LAMS is not always technically feasible and is associated with adverse events, such as bleeding, migration, infection, and dislodgement.[3] Moreover, the solid, necrotic tissue contained within WON is not usually draining spontaneously and has the potential of developing an infection, requiring necrosectomies. Especially during the performance of necrosectomy, dislodgement of the LAMS can happen. We present such a case of accidental LAMS migration/dislodgement occurring during a necrosectomy procedure with a LAMS salvage manoeuvre.
A 48-year-old woman was transferred from a peripheral to our tertiary hospital for an acute WON [Figure 1]. Under endosonographic and Doppler guidance, a 10 mm × 10 mm LAMS was placed from the posterior wall of the stomach into the WON. Despite an initial rapid improvement, the patient became septic 3 days after the placement of the LAMS. An Esophagogastroduodenoscopy (EGD) was performed for necrosectomy where the LAMS was dislodged accidentally. The stent was grasped with a biopsy forceps, removed orally, and cleaned. Then, a biopsy forceps was pushed through the scope and the LAMS was pulled over [Figure 2]a. The proximal end of the stent was then pushed into the therapeutic endoscope channel [Figure 2]b and the distal end of the stent was grasped with the forceps [Figure 2]c. The scope with the LAMS was carefully reintroduced into the stomach. Finally, the stent was put into the WON and the stent was deployed successfully under direct visualization by pushing forward the forceps [Video 1 [Additional file 1]]. | Figure 1: Abdomen computed tomography with a walled-off pancreatic necrotic collection measuring 132 x 61 mm.
Click here to view |
 | Figure 2: Re-positioning the lumen-apposing metal stents into the therapeutic endoscope channel
Click here to view |
Financial support and sponsorship
Nil.
Conflicts of interest
Payal Saxena is an Editorial Board Member of the journal. The article was subject to the journal's standard procedures, with peer review handled independently of this editor and his research groups.
Declaration of patient consent
The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given her consent for her images and other clinical information to be reported in the journal. The patient understands that her name and initials will not be published and due efforts will be made to conceal her identity, but anonymity cannot be guaranteed.
References | |  |
1. | Chen YI, Yang J, Friedland S, et al. Lumen apposing metal stents are superior to plastic stents in pancreatic walled-off necrosis: A large international multicenter study. Endosc Int Open 2019;7:E347-54. |
2. | Fabbri C, Luigiano C, Lisotti A, et al. Endoscopic ultrasound-guided treatments: Are we getting evidence based--A systematic review. World J Gastroenterol 2014;20:8424-48. |
3. | Fugazza A, Sethi A, Trindade AJ, et al. International multicenter comprehensive analysis of adverse events associated with lumen-apposing metal stent placement for pancreatic fluid collection drainage. Gastrointest Endosc 2020;91:574-83. |
[Figure 1], [Figure 2]
|