Evaluation of the ex-vivo porcine simulator on EUS-guided cystogastrostomy using lumen-apposing metal stent training


1 Department of Gastroenterology, Hepatopancreatology, and Digestive Oncology, Université Libre de Bruxelles, Brussels, Belgium; Department of Gastroenterology and Hepatology, Theodor Bilharz Research Institute, Cairo, Egypt
2 ROEYA Gastroenterology, Hepatology and Endoscopy Center, Cairo, Egypt
3 New Giza University, Cairo, Egypt
4 Department of Gastroenterology and Hepatology, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia
5 Department of Gastroenterology and Hepatology, King Fahad Medical City, Riyadh, Saudi Arabia
6 Department of Gastroenterology and Hepatology, Mansoura University, Egypt
7 Department of Gastroenterology, Alexandria Hospital, Egypt
8 Endemic Medicine Department, Helwan University, Egypt
9 Department of Endoscopy, Hospital of Ministry of Internal Affairs, Szczecin, Poland
10 Department of Gastroenterology & Hepatology, Singapore General Hospital, Singapore
11 Department of Gastroenterology, Juntendo University, Tokyo, Japan
12 Internal Medicine Department, Kasr Al-Ainy School of Medicine, Cairo University, Egypt
13 Department of Gastroenterology & Hepatology, Hospital Nord, Marseille, France
14 Department of Gastroenterology & Hepatology, Paoli Calmettes Institute, Marseille, France
15 Division of Gastroenterology, Department of Medicine, Siriraj Hospital, Bangkok, Thailand
16 Department of Hepato-Gastroenterology, Saint-Pierre Hospital, Brussels, Belgium
17 Division of Gastroenterology, Department of Medicine, Chulalongkom University, Bangkok, Thailand
18 Rajavithi Digestive Endoscopy Center, Bangkok, Thailand
19 Department of Endoscopy and Endoscopic Surgery, University of Tokyo, Tokyo, Japan

Date of Submission22-Apr-2021
Date of Acceptance30-Nov-2021
Date of Web Publication02-May-2022

Correspondence Address:
Mostafa Ibrahim
Department of Gastroenterology, Hepatopancreatology, and Digestive Oncology, Université Libre de Bruxelles, Brussels

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/EUS-D-21-00109

Rights and Permissions
  Abstract 


Bckground and Objectives: EUS-guided cystogastrostomy is a well-established advanced endoscopic technique with a steep-learning curve which necessitates an ex-vivo simulator that would allow for adequate training. The aim of this study is to evaluate the feasibility of the model in allowing training for EUS-guided cystogastrostomy using lumen-apposing metal stent (LAMS). Subjects and Methods: The model was created by ROEYA Training Center, Egypt, using native porcine tissue to create fluid collections simulating both cystic and solid lesions. It was designed and tested in advance while the hydrogel was added on-site. The simulator was evaluated prospectively in five training sessions involving 17 international experts. The task was to successfully deploy the LAMS to drain the created cyst. After using the simulator, the experts were asked to fill a questionnaire to assess their experience. The primary endpoint was overall satisfaction with the model as a training tool. Results: All of the experts were satisfied with the model as a tool to train endoscopists for the technique. 76.5% (n = 11) of the experts thought the model to be moderately realistic. Proper visualization was reported by 94.1% of the experts. All experts believed the lesions to be either slightly like or very similar to real lesions. The model was graded “easy” in difficulty by 11 of the experts. Conclusions: In all parameters assessed, the experts thought the model to be a useful tool for future training. This preliminary study suggests that the aforementioned simulator can be used to train endoscopists on using LAMS in a risk-free environment.

Keywords: cystogastrostomy, EUS-guided drainage, training model


How to cite this article:
Ibrahim M, Roshdy N, Taleb A, Alfadda A, Al-Lehibi A, Altonbary A, Galal A, El-Fouly A, Kozlowska A, Khor C, Isayama H, Okasha H, Barthet M, Giovannini M, Pausawasdi N, Eisendrath P, Kongkam P, Ratanachu-ek T, Nakai Y. Evaluation of the ex-vivo porcine simulator on EUS-guided cystogastrostomy using lumen-apposing metal stent training. Endosc Ultrasound 2022;11:201-7

How to cite this URL:
Ibrahim M, Roshdy N, Taleb A, Alfadda A, Al-Lehibi A, Altonbary A, Galal A, El-Fouly A, Kozlowska A, Khor C, Isayama H, Okasha H, Barthet M, Giovannini M, Pausawasdi N, Eisendrath P, Kongkam P, Ratanachu-ek T, Nakai Y. Evaluation of the ex-vivo porcine simulator on EUS-guided cystogastrostomy using lumen-apposing metal stent training. Endosc Ultrasound [serial online] 2022 [cited 2022 Jul 3];11:201-7. Available from: http://www.eusjournal.com/text.asp?2022/11/3/201/344243


  Introduction Top


EUS-guided cystogastrostomy is a technique that allows for drainage of peripancreatic fluid collections, namely pancreatic pseudocysts and walled-off necrosis. It is performed by creating a fistulous tract either through the stomach or duodenum and the cavity of the peripancreatic fluid collection.[1]

Pancreatic pseudocysts are fluid collections that accumulate in peripancreatic tissues as a complication of both acute and chronic pancreatitis. While pancreatic pseudocysts may resolve spontaneously, symptoms such as epigastric pain, vomiting, and sepsis may develop.[2] Pancreatic pseudocysts occur in up to 20% of patients with acute pancreatitis and 40% of the cases of chronic pancreatitis.[3] In addition, walled-off necrosis is the development of partially liquefied necrotic collection that is contained within a well-defined inflammatory wall. This occurs with acute necrotic collections that persist for over 4 weeks after the onset of necrotizing pancreatitis, a complication of acute pancreatitis that develops in 15% of patients.[4],[5]

Cyst/collection drainage is indicated in the case of symptomatic collections, enlarging cysts, infection, and walled-off pancreatic necrosis. Minimally invasive techniques include percutaneous drainage, endoscopic drainage, and minimally invasive surgery.[6]

Guidelines published by the American Society of Gastrointestinal Endoscopy and the European Society of Gastrointestinal Endoscopy recommend endoscopic drainage or percutaneous drainage of infected walled-off necrosis as a first-line intervention.[6],[7]

New larger diameter lumen-apposing metal stents (LAMS) have simplified the process of drainage. In two retrospective, multicenter studies evaluating the safety and efficacy of endoscopic therapy using LAMS for the drainage of pancreatic pseudocysts and walled-off necrosis, LAMS proved to effectively create a large and sustained cystogastrostomy.[8],[9]

Despite the wide range of indications, EUS-guided cystogastrostomy remains a challenging technique. Comprehensive knowledge of diagnostic and therapeutic EUS is necessary. Since patients with symptomatic fluid collections must be managed at highly qualified centers, ex-vivo simulators are a promising modality to be used by trainees to learn the targeted endoscopic skills in a safe, less stressful environment that does not subject patients to any risk.

This is a preliminary study that aims to evaluate the feasibility of the newly developed simulator in providing training for the EUS-guided cystogastrostomy using LAMS specifically, the Hot AXIOS™ system (Boston Scientific, Marlborough, MA).


  Subjects and Methods Top


Study setting

The present study took place between March 2018 and December 2019. ROEYA Training Center, Egypt, provided training simulators at five international endoscopy workshops with dedicated hands-on training sessions. The simulator was evaluated prospectively as 17 expert gastroenterologists were invited to evaluate the model. The group of experts included four from Europe, seven from the Middle East, and six from Asia.

Animal models

The models were designed and tested 2 weeks before each event. On the day of the event, the models were prepared with on-site injection of hydrogel. Injection of the gel into the cysts was done about 5–15 min before the training sessions.

Model preparation

The simulator was created by ROEYA Training Center using native porcine tissue to create the fluid collections. The model was derived and adapted from reports by Baron and DeSimio and Moryoussef et al.[10],[11] Three segments from the colon were used to create three cysts. Next, the cysts were sutured to the anterior gastric wall. These cysts were sutured in one of two locations: either near the pylorus of the stomach or the fundus. The cyst near the pylorus simulated a cystic lesion while the cyst sutured near the fundus was covered by the liver to simulate a solid lesion.

The stomach was then fixed in a copper tray to ensure proper conductivity of the electrical current of the EUS [Figure 1]. Finally, the whole specimen was covered with hydrogel to provide the optimum conducting medium for ultrasound waves. The EUS simulator facilitates the simulation of fluoroscopy without the use of X-ray using simulated fluoroscopy camera [Figure 2]. Fluoroscopy simulation was achieved by proper lighting in combination with transparent and nontransparent objects and without the use of harmful radiation. The camera was installed inside the simulator in an effort to create a substitute for fluoroscopy.
Figure 1: EUS view of the created cyst

Click here to view
Figure 2: Black and white image for the released stent (representative of X-RAY view)

Click here to view


EUS-cystogastrostomy procedure

Equipment

A linear echoendoscope with an ultrasound processor (EG-580 UT and SU1-H processor, FUJIFILM Medical Systems, Japan) was used along with an electrosurgical generator (VIO300D, ERBE, Tübingen, Germany) and the 15, 20 mm Hot AXIOS Stent and Electrocautery-Enhanced Delivery System (Boston Scientific, Marlborough, MA, USA).

The Hot AXIOS is a novel double-flanged covered self-expanding metallic stent with a “dumbbell” configuration that holds the tissue walls in apposition. The barbell shape of the stent decreases the possibility of stent migration.[12]

Procedure

The Hot AXIOS catheter was passed through the biopsy channel of the echoendoscope and advanced through the gastric mucosa under EUS guidance until the catheter was visualized.

Next, the device was energized using the electrosurgical generator that was preadjusted on the pure-cut setting. The catheter was advanced until the penetration of the targeted cyst was achieved [Figure 3].
Figure 3: EUS-guided puncture of the created lesion

Click here to view


When the catheter was fully inside the targeted cyst, the distal flange of the stent was deployed under the guidance of EUS until it was visible inside the cyst which confirmed that the distal flange was fully opened [Figure 4]. The distal flange was pulled backward toward the gastric wall. When the shape of the flange changed from flat to oval, the proximal flange was deployed.
Figure 4: Endoscopic image of the cyst after puncture achieved with full deployment of the stent

Click here to view


Finally, the echoendoscope was gently withdrawn while the catheter control hub was simultaneously slowly pushed downward to allow for the release of the proximal flange from the working channel.

The simulator allows for multiple punctures of the created lesions; therefore, on each simulator, an average of 5–7 EUS cyst gastrostomy procedures using LAMS can be performed.

Study design

Once the model was designed, it was first tested by its designers for its ability to allow EUS-guided cystogastrostomy procedures. The task was to successfully deploy the Hot AXIOS™ system to drain the created cyst. Throughout the study duration, 17 international experts were asked to perform the procedure themselves using the training model. All of the experts have more than 10 years of endoscopic experience and perform a variety of EUS procedures including EUS cystogastrostomy along with other advanced techniques such as EUS-guided biliary drainage and EUS celiac plexus block.

Study end-points

The experts were asked to fill a questionnaire within a week after the use of the training model.

The primary endpoint was overall satisfaction with the simulator as a training tool for EUS-guided cystogastrostomy.

Secondary endpoints regarding the training model included:

  • Impression of realism of the model
  • Visualization of the target lesion
  • Anatomical accuracy of the model
  • Overall difficulty of the model
  • Impression of clinical benefit
  • Effect on performance time
  • Effect on postprocedure side effects.



  Results Top


Overall, the experts considered the model an adequate tool to train endoscopists on EUS-guided cystogastrostomy using LAMS.

Evaluation of secondary endpoints is included below [Figure 5],[Figure 6],[Figure 7],[Figure 8],[Figure 9],[Figure 10],[Figure 11].
Figure 5: Results of expert questionnaire when asked about their impression of realism

Click here to view
Figure 6: Results of expert questionnaire when asked about visualization of the target lesion

Click here to view
Figure 7: Results of expert questionnaire when asked about anatomical accuracy

Click here to view
Figure 8: Results of expert questionnaire when asked about overall difficulty of the model

Click here to view
Figure 9: Results of expert questionnaire when asked if training on model helped their clinical practice

Click here to view
Figure 10: Results of expert questionnaire when asked about procedure time after training

Click here to view
Figure 11: Results of expert questionnaire when asked about postprocedure side effects after training

Click here to view


The experts assessed the realism of the model in regards to emulating lesions found in real-life patients. 64.7% (n = 11) thought the lesions to be “moderately realistic” while 35.3% (n = 6) thought it to be “very realistic.” None of the experts thought the model to be “unrealistic” [Figure 5].

When asked about the visibility of the target lesion, 16 (94.1%) of the experts thought the lesion to be “properly visualized” using the provided equipment while only one expert (5.9%) believed it to be “hardly visualized.” None of the experts were unable to visualize the lesion [Figure 6].

The experts compared the anatomical accuracy of the created lesions to actual, real lesions as would be seen in patients. 76.5% (n = 13) thought the lesions to be “slightly like the actual lesions” while 23.5% (n = 4) thought the lesions to be “very similar.” None of the experts thought the created lesions to be completely dissimilar to actual lesions [Figure 7].

The experts were asked to rate the overall difficulty of the cyst drainage model on a scale of easy, moderate difficulty, and very difficult. “Easy” was defined as the ability of the procedure to be performed by any trainee using the model. “Moderate difficulty” suggests that the model can only be performed by experienced trainees while “very difficult” indicates that only the experts can perform the procedure. Of 17, 11 of the experts (64.7%) found the model to be “easy” while 6 or 35.3% found it to be of “moderate difficulty” [Figure 8].

Three of the included survey questions were regarding the expert's perception of experience gained after using the model [Figure 9],[Figure 10],[Figure 11]. When asked if the model was helpful in the expert's clinical practice, 15 experts (88.2%) answered “yes” while two experts (11.8%) responded “no” [Figure 9].

Regarding performance time, 13 experts (76.5%) reported that their performance time decreased after the training [Figure 10].

When asked if the training decreased postprocedure side-effects, 10 experts (58.9%) reported to have decreased complications while seven experts (41.2%) found that the training had no effect [Figure 11].


  Discussion Top


EUS-guided drainage of peripancreatic fluid collections has become one of the most technically demanding procedures in gastrointestinal endoscopy. However, these advanced techniques, including EUS-cystogastrostomy using LAMS, require certain skills to be acquired over a learning curve. Hence, specific and validated models are necessary to provide safe and efficient training to endoscopists to achieve proficiency in a risk-free environment.

The results of this study demonstrated that expert opinion found the model favorable in terms of realism, visualization of the target lesion, and anatomical accuracy [Figure 5],[Figure 6],[Figure 7]. Most of the experts (67.4%) rated the model as “easy” which means that any trainee can use the model without the need of rich experience in EUS [Figure 8]. The purpose was to evaluate whether a trainee would be able to use the model with ease even with step-by-step instruction from a mentor or expert which is necessary during training. All of the experts believed the model to be an efficient tool to be used for endoscopy training in the evaluated technique.

Our study has limitations. Since we only included EUS experts in this preliminary study, the effect of the model on their clinical practice could not be fully assessed. However, we have included a few questions [Figure 9],[Figure 10],[Figure 11] that were asked in the 6-month period following the training. Most of the experts found the model to be helpful in their clinical practice. Overall, the model improved most of the expert's techniques by decreasing performance time, but there was not much effect on postprocedure side effects on the patients. While the purpose of the study was to act as a preliminary evaluation of the training model, less-experienced GI-fellow input is needed to further validate the model.

Our main finding is that the model is considered an adequate tool by experts, and therefore, this study serves as a preliminary validation of the training model.


  Conclusions Top


In conclusion, we recommend the use of this model for the training of complicated EUS procedures, specifically, EUS-guided cystogastrostomy using LAMS. These procedures require adequate training and experience. While this study was focused on receiving feedback from endoscopists who are experienced in the technique, further work is needed to conduct a study focused on endoscopists with less experience.

Financial support and sponsorship

Nil.

Conflicts of interest

Marc Giovannini is a Founding Editors- in-Chief of the journal, and Hussein Okasha, Nonthalee Pausawasdi, Pradermchai Kongkam and Thawee Ratanachu-ek are Editorial Board Members. The article was subject to the journal's standard procedures, with peer review handled independently of these editors and their research groups.



 
  References Top

1.
Renelus BD, Jamorabo DS, Gurm HK, et al. Comparative outcomes of endoscopic ultrasound-guided cystogastrostomy for peripancreatic fluid collections: A systematic review and meta-analysis. Ther Adv Gastrointest Endosc 2019;12:1-11.  Back to cited text no. 1
    
2.
Habashi S, Draganov PV. Pancreatic pseudocyst. World J Gastroenterol 2009;15:38-47.  Back to cited text no. 2
    
3.
Lerch MM, Stier A, Wahnschaffe U, et al. Pankreaspseudozysten: Abwarten, endoskopisch drainieren, resezieren? Dtsch Arztebl 2009;106:614-21.  Back to cited text no. 3
    
4.
Sarr MG, Banks PA, Bollen TL, et al. The new revised classification of acute pancreatitis 2012. Surg Clin North Am 2013;93:549-62.  Back to cited text no. 4
    
5.
da Costa DW, Boerma D, van Santvoort HC, et al. Staged multidisciplinary step-up management for necrotizing pancreatitis. Br J Surg 2014;101:e65-79.  Back to cited text no. 5
    
6.
ASGE Standards of Practice Committee; Muthusamy VR, Chandrasekhara V, et al. The role of endoscopy in the diagnosis and treatment of inflammatory pancreatic fluid collections. Gastrointest Endosc 2016;83:481-8.  Back to cited text no. 6
    
7.
Arvanitakis M, Dumonceau JM, Albert J, et al. Endoscopic management of acute necrotizing pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) evidence-based multidisciplinary guidelines. Endoscopy 2018;50:524-46.  Back to cited text no. 7
    
8.
Siddiqui AA, Adler DG, Nieto J, et al. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: A large retrospective, multicenter U.S. experience (with videos). Gastrointest Endosc 2016;83:699-707.  Back to cited text no. 8
    
9.
Sharaiha RZ, Tyberg A, Khashab MA, et al. Endoscopic therapy with lumen-apposing metal stents is safe and effective for patients with pancreatic walled-off necrosis. Clin Gastroenterol Hepatol 2016;14:1797-803.  Back to cited text no. 9
    
10.
Moryoussef F, Leblanc S, Bertucat A, et al. Comparative evaluation of two porcine ex vivo models for training in endoscopic ultrasound-guided drainage of pancreatic fluid collections. Endosc Int Open 2017;5:E1020-6.  Back to cited text no. 10
    
11.
Baron TH, DeSimio TM. New ex-vivo porcine model for endoscopic ultrasoundguided training in transmural puncture and drainage of pancreatic cysts and fluid collections (with videos). Endosc Ultrasound 2015;4:34-9.  Back to cited text no. 11
    
12.
Rodrigues-Pinto E, Baron TH. Evaluation of the AXIOS stent for the treatment of pancreatic fluid collections. Expert Rev Med Devices 2016;13:793-805.  Back to cited text no. 12
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10], [Figure 11]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
   Abstract
  Introduction
  Subjects and Methods
  Results
  Discussion
  Conclusions
   References
   Article Figures

 Article Access Statistics
    Viewed420    
    Printed18    
    Emailed0    
    PDF Downloaded24    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]