Adverse events associated with AXIOS stents: Insights from the manufacturer and user facility device experience database


1 Department of Gastroenterology and Hepatology, University of Utah Health, Salt Lake City, Utah, USA
2 Department of Medical Sciences, Section of Gastroenterology, University of Foggia, Foggia, Italy
3 St. Georges University School of Medicine, True Blue, Grenada, WI, USA
4 Division of Gastroenterology, Stanford University, California, USA
5 Center for Advanced Therapeutic Endoscopy, Porter Adventist Hospital/PEAK Gastroenterology, Denver, Colorado, USA

Correspondence Address:
Douglas G Adler
Center for Advanced Therapeutic Endoscopy, Porter Adventist Hospital/PEAK Gastroenterology, Denver, Colorado
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/EUS-D-21-00096

Rights and Permissions

Background and Objectives: The AXIOS stent is indicated for transgastric or transduodenal drainage of symptomatic pancreatic pseudocysts and symptomatic walled off necrosis. The AXIOS stent functions as a conduit which allows solid and liquid pancreatic fluid collections (PFC) contents to pass into the luminal GI tract and also allows the passage of standard and therapeutic endoscopes into the PFC to perform endoscopic debridement. We aim to investigate the number and type of complications associated with AXIOS stents. Materials and Methods: We analyzed postmarketing surveillance data from the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database January 2016 to February 2021. Results: During the study period, approximately 588 reports with 579 device issues and 250 patient complications were identified. Most device complications were due to stent positioning problems or stent malpositioning (n = 206; 35.6%), followed by stent migration (n = 72; 12.4%), premature deployment (n = 61; 10.5%), material integrity (n = 56; 9.6%), deployment failure (n = 47; 8.1%), and difficulty removing the stent (n = 45; 7.7%). The most reported patient adverse events were hemorrhage/bleeding (n = 81; 32.4%), perforation (n = 26; 10.4%), pain (n = 22; 8.8%), unspecified infection (n = 20; 8.0%), and death (n = 17; 6.8%). Conclusions: Findings from the MAUDE database highlight patient and device complications which endoscopists should be aware of before AXIOS stent placement.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1797    
    Printed32    
    Emailed0    
    PDF Downloaded46    
    Comments [Add]    

Recommend this journal