• Users Online:281
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 

 Table of Contents  
IMAGES AND VIDEOS
Year : 2022  |  Volume : 11  |  Issue : 3  |  Page : 241-242

EUS-guided hepaticogastrostomy with contrast-enhanced harmonic imaging (with video)


Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan

Date of Submission19-Apr-2021
Date of Acceptance23-Sep-2021
Date of Web Publication25-Jan-2022

Correspondence Address:
Masayuki Kitano
Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama 641-8509
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/EUS-D-21-00107

Rights and Permissions

How to cite this article:
Tamura T, Kitano M, Hatamaru K. EUS-guided hepaticogastrostomy with contrast-enhanced harmonic imaging (with video). Endosc Ultrasound 2022;11:241-2

How to cite this URL:
Tamura T, Kitano M, Hatamaru K. EUS-guided hepaticogastrostomy with contrast-enhanced harmonic imaging (with video). Endosc Ultrasound [serial online] 2022 [cited 2022 Jun 25];11:241-2. Available from: http://www.eusjournal.com/text.asp?2022/11/3/241/336597

EUS-guided hepaticogastrostomy (EUS-HGS) is useful for biliary drainage in patients in whom ERCP fails. In performing EUS-HGS, it is important to detect a dilated intrahepatic bile duct (IHBD). However, it may be difficult to detect the IHBD in patients who have bile duct filled with sludge.

Contrast-enhanced harmonic imaging (CHI) has been reported to be useful in determining the borderline between the fluid space and tissue.[1],[2],[3],[4] This report describes the usefulness of EUS-HGS with CHI (EUS-HGS-CHI) for the identification of otherwise difficult to detect IHBD [Video 1 [Additional file 1]].

The left hepatic lobe was viewed under fundamental B-mode EUS (FB-EUS). If FB-EUS failed to detect clearly the dilated IHBD [Figure 1]a, we used CHI. The monitor was changed to CHI mode. Bolus intravenous administration of Sonazoid enhanced the liver parenchyma but not debris, increasing the contrast between the fluid space in the IHBD and the hepatic parenchyma, which made it easy to puncture the IHBD [Figure 1]b. We punctured the IHBD with a 19-G EUS-FNA needle under CHI and confirmed access to the bile duct after aspiration of bile and injection of contrast medium into the IHBD. After insertion of a 0.025-inch guidewire through the needle into the bile duct, we dilated the puncture site in the gastric wall using a 4-mm balloon dilation catheter and finally deployed a covered metal stent (10 mm × 10 cm, Niti-S Biliary Cover Stent; Taewoong Medical, Seoul, S. Korea) between the IHBD and the gastric wall.
Figure 1: EUS-guided hepaticogastrostomy with contrast-enhanced harmonic imaging. (a) Fundamental B-mode EUS imaging showing the left hepatic lobe. The dilated intrahepatic bile duct was unclear. (b) Contrast-enhanced harmonic EUS after a bolus injection of ultrasound contrast agent, showing enhancement of the liver parenchyma, but not of debris, as well as a clearly visible dilated intrahepatic bile duct

Click here to view


CH-EUS is superior to FB-EUS in detecting dilated IHBD filled with debris. Under FB-EUS, debris and liver parenchyma appear isoechoic. However, under CH-EUS, the hepatic parenchyma is enhanced because the Sonazoid are phagocytosed by Kupffer cells in the liver, whereas the bile ducts are not enhanced because of the absence of Kupffer cells.[5] Therefore, intrahepatic bile ducts with debris can be detected more easily under CH-EUS than under FB-EUS.

In conclusion, CHI can play an important role in identifying targeted IHBDs that are difficult to detect by fundamental B-mode imaging during EUS-HGS.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Kamata K, Takenaka M, Kitano M, et al. Contrast-enhanced harmonic endoscopic ultrasonography for differential diagnosis of localized gallbladder lesions. Dig Endosc 2018;30:98-106.  Back to cited text no. 1
    
2.
Tamura T, Kitano M, Kawai M, et al. Contrast-enhanced harmonic endoscopic ultrasound-guided drainage of a postoperative pancreatic fistula. Endoscopy 2020;52:E174-5.  Back to cited text no. 2
    
3.
Tamura T, Yamashita Y, Kawaji Y, et al. Endoscopic ultrasound-guided fine needle aspiration with contrast-enhanced harmonic imaging for diagnosis of gallbladder tumor (with video). J Hepatobiliary Pancreat Sci 2021;28:e1-3.  Back to cited text no. 3
    
4.
Minaga K, Kitano M, Yoshikawa T, et al. Hepaticogastrostomy guided by real-time contrast-enhanced harmonic endoscopic ultrasonography: A novel technique. Endoscopy 2016;48 Suppl 1:E228-9.  Back to cited text no. 4
    
5.
Park HS, Kim YJ, Yu MH, et al. Real-time contrast-enhanced sonographically guided biopsy or radiofrequency ablation of focal liver lesions using perflurobutane microbubbles (sonazoid): Value of Kupffer-phase imaging. J Ultrasound Med 2015;34:411-21.  Back to cited text no. 5
    


    Figures

  [Figure 1]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
   References
   Article Figures

 Article Access Statistics
    Viewed934    
    Printed39    
    Emailed0    
    PDF Downloaded31    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]