• Users Online:156
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
 
ORIGINAL ARTICLE
Ahead of Print

Technical feasibility and safety of one-step deployment of EUS-guided hepaticogastrostomy using an 8-mm diameter metal stent with a fine-gauge stent delivery system (with video)


 2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan

Correspondence Address:
Takeshi Ogura,
2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka 569-8686
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/EUS-D-20-00206

PMID: 34427190

Background and Objectives: Adverse events (AEs) such as bile peritonitis or pneumoperitoneum might occur during procedural steps for EUS-guided hepaticogastrostomy (HGS), such as during device exchange and after fistula dilation until stent deployment. Reducing the steps to the EUS-HGS procedure might therefore be ideal to prevent the occurrence of AEs. Recently, a novel, fully covered self-expandable metal stent (FCSEMS) has become available. Because of the fine-gauge stent delivery system (5.9Fr), fistula dilation might not be needed before stent deployment during EUS-HGS. The aim of this pilot study was to evaluate the technical feasibility and safety of one-step EUS-HGS using a novel 8-mm diameter FCSEMS. Patients and Methods: The primary outcome in this study was technical success, and the secondary outcomes were procedure- and stent-related AEs and clinical success. The technical success of one-step EUS-HGS was defined as successful FCSEMS deployment without any fistula dilation. Procedure time was measured from scope insertion to successful FCSEMS deployment. Results: One-step EUS-HGS using the novel FCSEMS was attempted on 14 patients. Technical success with a short procedure time (median: 7 min) and clinical success were obtained in all patients. In addition, procedure-related AEs such as bleeding, bile peritonitis, and stent migration during the procedure were not observed in any patients. Conclusions: One-step EUS-HGS using the novel FCSEMS with a fine-gauge stent delivery system is technically feasible and shortens the procedure time with no requirement for additional fistula dilation, resulting in a potential reduction in procedure-related AEs.


Print this article
Search
 Back
 
  Search Pubmed for
 
    -  Ogura T
    -  Ueno S
    -  Okuda A
    -  Nishioka N
    -  Yamada M
    -  Matsuno J
    -  Ueshima K
    -  Yamamoto Y
    -  Higuchi K
 Citation Manager
 Article Access Statistics
 Reader Comments
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed433    
    PDF Downloaded4    

Recommend this journal